Submersible Cable |
|
 |
| Application : |
| Ideal for irrigation pumps, drinking water supply pumps, offshore drilling rigs, fire fighting equipment , sewage treatment plants, sea water / river water handling equipment. |
| Standards : |
| IS : 694 , BS 6500 |
| Conductor : |
Class 5 plain stranded flexible copper conductors to IS : 8130 or BS EN 60228:2005
(previously BS6360), VDE0295 |
| Insulation : |
| PVC (Polyvinyl Chloride) |
| Sheath : |
| PVC (Polyvinyl Chloride) |
| Sheath Colour : |
| Black , Gray , Yellow , Blue |
| Voltage Rating : |
| Up to 1100 Volts. |
| Requirement of Oxygen to Catch Fire (% in air) |
| > 30 |
| Temperature Required to catch fire ( with 21% oxygen) |
| > 2500 C. |
| Visibility during Cable burning (%) : |
| < 35 |
|
|
(1) Copper Conductor (2) PVC Insulation of Cores ( Red, yellow , blue)
(3) PVC Sheath |
| 3 Core Flat Cables as per IS : 694 |
| Conductor |
Overall Dimensions |
Current carrying capacity @400 C. Amps. |
Area
Sq.mm. |
No. of Cond. / Dia. mm |
Width (Approx.) ‘W’ mm |
Height (Approx.) ‘H’ mm |
| * As per Conductor Class 2 of IS : 8130 : 1984 |
| 10.0 |
140 / 0.30 |
23.7 |
9.9 |
42 |
| 16.0 |
226 / 0.30 |
28.0 |
11.4 |
57 |
| 25.0 |
354 / 0.30 |
35.5 |
14.7 |
72 |
| 35.0 |
495 / 0.30 |
39.5 |
16.2 |
90 |
| 50.0 |
703 / 0.30 |
45.5 |
18.3 |
115 |
** The No. of wires and Strand Dia. Will be such as to satisfy the requirement of conductor resistance as per IS : 8130
** 4 & 5 Core Flat cable are available on request. |
| Conductor |
Overall Dimensions |
Current carrying capacity @400 C. Amps. |
Area
Sq.mm. |
No. of Cond. / Dia. mm |
Width (Approx.) ‘W’ mm |
Height (Approx.) ‘H’ mm |
| 1.5 |
22 / 0.30* |
12.0 |
5.60 |
14 |
| 2.5 |
36 / 0.30* |
14.0 |
6.40 |
18 |
| * As per Conductor Class 2 of IS : 8130 : 1984 |
| 4.0 |
56 / 0.30 |
16.5 |
7.4 |
26 |
| 6.0 |
84 / 0.30 |
18.7 |
7.9 |
31 |
| 70.0 |
360 / 0.50 |
51.0 |
20.0 |
143 |
| 95.0 |
475 / 0.50 |
60.0 |
23.5 |
165 |
|
|
| |
| Rating factors for low voltage : |
| Multiply the full load current of submersible motors by factors given below for different supply voltages & select the right cable. |
| Voltage |
415 |
400 |
350 |
300 |
275 |
250 |
| Rating Factor |
1 |
1.05 |
1.15 |
1.25 |
1.30 |
1.35 |
|
| |
| |
| Derating Factors : |
| Multiply the full load current of submersible motors by factors given below for various ambient temperatures. |
| Ambient Temperature C. |
30 |
35 |
40 |
45 |
50 |
| Rating Factor |
1.09 |
1.04 |
1.00 |
0.95 |
0.77 |
|
| |
SELECTION GUIDE FOR 3 CORE FLAT CABLES :
CABLES SELECTION CHART AT 400 C. 415 V. (WITH DOL STARTER) |
| Submersible Motors |
Size of Cable in Sq.mm at Different Length in Mtrs. |
| H.P. |
Full Load Current Amps. |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
130 |
140 |
180 |
| 5 |
7.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
2.5 |
2.5 |
4 |
4 |
| 7.5 |
11 |
1.5 |
1.5 |
1.5 |
1.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
6 |
| 10 |
15 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
4 |
6 |
6 |
| 12.5 |
19 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
10 |
| 15 |
22.5 |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
10 |
10 |
| 17.5 |
26 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
10 |
10 |
10 |
10 |
| 20 |
28.4 |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
10 |
10 |
10 |
16 |
| 25 |
35.6 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
| 30 |
42.3 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
16 |
| 35 |
50.4 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
| 40 |
58.1 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
| 45 |
62.1 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
| 50 |
67.5 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
35 |
| 55 |
73.8 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
| 60 |
81.0 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
| 65 |
87.3 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
35 |
| 70 |
93.6 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
| 75 |
100.8 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
| 80 |
108.0 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
| |
| CABLES SELECTION CHART AT 400 C. 415 V. ( WITH STAR DELTA STARTER – DOUBLE CABLE ) |
| Submersible Motors |
Size of Cable in Sq.mm at Different Length in Mtrs. |
| H.P. |
Full Load Current Amps. |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
130 |
140 |
180 |
| 5 |
7.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
2.5 |
2.5 |
2.5 |
| 7.5 |
11 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
2.5 |
4 |
4 |
4 |
| 10 |
15 |
1.5 |
1.5 |
1.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
6 |
6 |
| 12.5 |
19 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
6 |
6 |
6 |
| 15 |
22.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
| 17.5 |
26 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
| 20 |
28.4 |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
10 |
10 |
| 25 |
35.6 |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
10 |
10 |
10 |
16 |
| 30 |
42.3 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
10 |
10 |
10 |
10 |
16 |
| 35 |
50.4 |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
10 |
10 |
10 |
16 |
16 |
| 40 |
58.1 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
16 |
| 45 |
62.1 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
16 |
| 50 |
67.5 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
16 |
25 |
| 55 |
73.8 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
16 |
16 |
16 |
25 |
| 60 |
81.0 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
25 |
| 65 |
87.3 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
25 |
| 70 |
93.6 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
35 |
| 75 |
100.8 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
25 |
25 |
35 |
| 80 |
108.0 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
35 |
|