Premium EPDM rubber 3 & 4 core flat submersible cables in AWG sizes designed for reliable deep well pump power connections. Featuring high-flexibility copper conductors with heavy-duty rubber insulation and sheath, they excel in resisting oil, chemicals, ozone, water and mechanical stress. Ideal for demanding submersible and industrial pumping applications requiring AWG sizing.
Conductor: Finely stranded bare flexible copper conductor.
Insulation: EPDM Rubber
Sheath: Black \ Blue heavy duty EPDM.
Core Colours 3 core: Red, Yellow, Black, || 4Core :Red, Yellow, Black, Green
For continuous use in deep well to supply power to submersible motors for the depth upto 500 mtrs.
Meets the requirement of CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.
| Conductor Size (AWG) | Nos and Dia. of wire (Nos. x mm) | Core Dia. (mm) | Nominal Sheath Thickness (mm) | Cable Overall Dimension (mm) |
|---|---|---|---|---|
| 14 | 41×0.254 | 3.60 | 1.15 | 13.30×6.20 |
| 12 | 65×0.254 | 4.30 | 1.15 | 15.60×7.00 |
| 10 | 105×0.254 | 5.10 | 1.15 | 17.70×7.40 |
| 8 | 168×0.254 | 6.30 | 1.40 | 22.30×9.30 |
| 6 | 226×0.254 | 7.60 | 1.40 | 26.30×10.80 |
| 4 | 420×0.254 | 9.90 | 2.00 | 32.30×13.10 |
| 2 | 665×0.254 | 11.10 | 2.00 | 35.90×14.30 |
| 1 | 817×0.254 | 13.60 | 2.20 | 45.50×18.30 |
| 1/0 | 1045×0.254 | 13.60 | 2.20 | 45.50×18.30 |
| 2/0 | 1330×0.254 | 15.60 | 2.20 | 51.00×21.00 |
| 3/0 | 1672×0.254 | 18.00 | 2.40 | 61.00×23.50 |
| 4/0 | 2116×0.254 | 19.80 | 2.65 | 65.00×25.20 |
| 250 MCM | 2503×0.254 | 20.60 | 2.80 | 68.00×28.00 |
| Conductor Size (AWG) | Nos and Dia. of wire (Nos. x mm) | Ground Conductor Size (mm) | Core Dia. (mm) | Nominal Sheath Thickness (mm) | Cable Overall Dimension (mm) |
|---|---|---|---|---|---|
| 14 | 41×0.254 | 14 | 3.85 | 1.15 | 18.00×6.50 |
| 12 | 65×0.254 | 12 | 4.50 | 1.15 | 21.00×7.60 |
| 10 | 105×0.254 | 10 | 5.30 | 1.15 | 24.30×7.90 |
| 8 | 168×0.254 | 10 | 6.50 | 1.40 | 29.70×9.90 |
| 6 | 266×0.254 | 8 | 8.00 | 2.00 | 36.00×11.80 |
| 4 | 420×0.254 | 8 | 10.10 | 2.00 | 45.10×14.70 |
| 2 | 665×0.254 | 6 | 11.30 | 2.20 | 50.10×16.20 |
| 1 | 817×0.254 | 6 | 13.60 | 2.20 | 58.10×19.00 |
| 1/0 | 1045×0.254 | 6 | 13.60 | 2.20 | 58.10×19.00 |
| 2/0 | 1330×0.254 | 4 | 15.60 | 2.20 | 66.50×21.50 |
| 3/0 | 1672×0.254 | 2 | 18.00 | 2.65 | 77.30×23.50 |
| 4/0 | 2116×0.254 | 2 | 19.80 | 3.85 | 87.00×27.80 |
The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 In view of continuous improvements in our design and process, specifications given here in are subject change without notice